Blowout preventer not tested to shear pipe

The blowout preventer that failed to stop last year’s Gulf of Mexico oil spill hadn’t been tested to see if it could cut through a bent drill pipe, said a senior official of the company that made the device.

04/26/2011


The blowout preventer that failed to stop last year’s Gulf of Mexico oil spill hadn’t been tested to see if it could cut through a bent drill pipe, said a senior official of the company that made the device.

The firm hired by the government to examine the 300-ton device after they brought it up from the seafloor concluded the blind shear rams couldn’t pinch the well shut by cutting through the drill pipe. That’s because the pipe was off center. The firm faulted the design of the Cameron-made blowout preventer.

Cameron vice president David McWhorter told a federal investigative panel he couldn’t say if the company designed the device to cut through a bent drill pipe. He said it did not undergo testing for that possibility before the disaster.

“I am not going to hazard an opinion,” said McWhorter, who works in Cameron’s division that handles engineering and quality for drilling systems.

The testimony wrapped up the seventh series of hearings before the joint U.S. Coast Guard-Bureau of Ocean Energy Management Regulation and Enforcement panel, which is investigating the causes of the Deepwater Horizon rig explosion off Louisiana last April 20. The blast killed 11 workers and led to the worst offshore oil spill in U.S. history.

The panel should release a preliminary statement within the next few weeks and will issues a full report in July.

In earlier testimony, Ralph Linenberger, a BP consultant hired to monitor the blowout preventer examination on behalf of the company, questioned the findings of testing firm Det Norske Veritas. Among other things, he said he did not see evidence the drill pipe had buckled, as DNV concluded it had.

“It looked fairly straight to me,” Linenberger said.

He also said DNV did not conduct any substantive testing that would look at the possibility of maintenance of the blowout preventer being a potential factor in the device’s failure.

Transocean owned the rig that exploded and was responsible for maintaining the blowout preventer. BP was leasing the rig from Transocean and owned the undersea well that blew out.



Top Plant
The Top Plant program honors outstanding manufacturing facilities in North America.
Product of the Year
The Product of the Year program recognizes products newly released in the manufacturing industries.
System Integrator of the Year
Each year, a panel of Control Engineering and Plant Engineering editors and industry expert judges select the System Integrator of the Year Award winners in three categories.
May 2018
Electrical standards, robots and Lean manufacturing, and how an aluminum packaging plant is helping community growth.
April 2018
2017 Product of the Year winners, retrofitting a press, IMTS and Hannover Messe preview, natural refrigerants, testing steam traps
March 2018
SCCR, 2018 Maintenance study, and VFDs in a washdown environment.
June 2018
Machine learning, produced water benefits, programming cavity pumps
April 2018
ROVs, rigs, and the real time; wellsite valve manifolds; AI on a chip; analytics use for pipelines
February 2018
Focus on power systems, process safety, electrical and power systems, edge computing in the oil & gas industry
Spring 2018
Burners for heat-treating furnaces, CHP, dryers, gas humidification, and more
April 2018
Implementing a DCS, stepper motors, intelligent motion control, remote monitoring of irrigation systems
February 2018
Setting internal automation standards

Annual Salary Survey

After two years of economic concerns, manufacturing leaders once again have homed in on the single biggest issue facing their operations:

It's the workers—or more specifically, the lack of workers.

The 2017 Plant Engineering Salary Survey looks at not just what plant managers make, but what they think. As they look across their plants today, plant managers say they don’t have the operational depth to take on the new technologies and new challenges of global manufacturing.

Read more: 2017 Salary Survey

The Maintenance and Reliability Coach's blog
Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
One Voice for Manufacturing
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Maintenance and Reliability Professionals Blog
The Society for Maintenance and Reliability Professionals an organization devoted...
Machine Safety
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
Research Analyst Blog
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Marshall on Maintenance
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
Lachance on CMMS
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.
Maintenance & Safety
The maintenance journey has been a long, slow trek for most manufacturers and has gone from preventive maintenance to predictive maintenance.
Industrial Analytics
This digital report explains how plant engineers and subject matter experts (SME) need support for time series data and its many challenges.
IIoT: Operations & IT
This digital report will explore several aspects of how IIoT will transform manufacturing in the coming years.
Randy Steele
Maintenance Manager; California Oils Corp.
Matthew J. Woo, PE, RCDD, LEED AP BD+C
Associate, Electrical Engineering; Wood Harbinger
Randy Oliver
Control Systems Engineer; Robert Bosch Corp.
Data Centers: Impacts of Climate and Cooling Technology
This course focuses on climate analysis, appropriateness of cooling system selection, and combining cooling systems.
Safety First: Arc Flash 101
This course will help identify and reveal electrical hazards and identify the solutions to implementing and maintaining a safe work environment.
Critical Power: Hospital Electrical Systems
This course explains how maintaining power and communication systems through emergency power-generation systems is critical.
click me