UPS maintenance bypass cabinet integrates three functions

This UPS bypass cabinet system enables IT and facility managers to integrate power transformation, power distribution and maintenance bypass into a single cabinet. This three-in-one cabinet complements a rack-based 60 kVA UPS parallel system, and is designed to allow the transfer of power to full system bypass to perform service, testing and maintenance on up to a full rack of UPS units without interrupting power to the critical load.

07/01/2008


BladeUPS Maintenance Bypass Cabinet

The Powerware BladeUPS Maintenance Bypass Cabinet (MBC) enables IT and facility managers to integrate power transformation, power distribution and maintenance bypass into a single cabinet. This three-in-one cabinet complements a rack-based 60 kVA Powerware BladeUPS parallel system, and is designed to allow the transfer of power to full system bypass to perform service, testing and maintenance on up to a full rack of Powerware BladeUPS without interrupting power to the critical load.

Instead of having a separate power distribution unit or step-down transformer, distribution cabinet and bypass cabinet, this system combines the convenience and simplicity of all three functions in one factory-tested box. The integral maintenance bypass is a mechanical way to bypass the internal components of the UPS while still sending utility power to the load. If the UPS must be repaired internally, it can be completely isolated from utility power and a technician can safely perform service without voltage present.

The unit uses a TP-1 transformer, which meets the U.S. Department of Energy standard for the Energy Star program, to step down utility power from 480 V to 208/120 V to provide electrical isolation and appropriate input voltage for the UPS modules. With high efficiency, even at low loads, the transformer yields significant savings in utility costs.

Additional features include:

• Integrated power distribution with two 42-pole Cutler Hammer panelboards for easy installation of additional breakers in the field

• Multi-function design that integrates electrical isolation, voltage transformation, electrical distribution and maintenance bypass; simplifies the data center architecture and conserves floor space, compared to separate maintenance bypass and power distribution systems

• Free-standing design that harmonizes with other data center equipment and easy installation and use with flexible access and deployment options.

Eaton Corp.
www.eaton.com/powerware





No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2015 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
2015 Top Plant: Phoenix Contact, Middletown, Pa.; 2015 Best Practices: Automation, Electrical Safety, Electrical Systems, Pneumatics, Material Handling, Mechanical Systems
A cool solution: Collaboration, chemistry leads to foundry coat product development; See the 2015 Product of the Year Finalists
Raising the standard: What's new with NFPA 70E; A global view of manufacturing; Maintenance data; Fit bearings properly
Special report: U.S. natural gas; LNG transport technologies evolve to meet market demand; Understanding new methane regulations; Predictive maintenance for gas pipeline compressors
Cyber security cost-efficient for industrial control systems; Extracting full value from operational data; Managing cyber security risks
Drilling for Big Data: Managing the flow of information; Big data drilldown series: Challenge and opportunity; OT to IT: Creating a circle of improvement; Industry loses best workers, again
Migrating industrial networks; Tracking HMI advances; Making the right automation changes
Understanding transfer switch operation; Coordinating protective devices; Analyzing NEC 2014 changes; Cooling data centers
Upgrading secondary control systems; Keeping enclosures conditioned; Diagnostics increase equipment uptime; Mechatronics simplifies machine design

Annual Salary Survey

After almost a decade of uncertainty, the confidence of plant floor managers is soaring. Even with a number of challenges and while implementing new technologies, there is a renewed sense of optimism among plant managers about their business and their future.

The respondents to the 2014 Plant Engineering Salary Survey come from throughout the U.S. and serve a variety of industries, but they are uniform in their optimism about manufacturing. This year’s survey found 79% consider manufacturing a secure career. That’s up from 75% in 2013 and significantly higher than the 63% figure when Plant Engineering first started asking that question a decade ago.

Read more: 2014 Salary Survey: Confidence rises amid the challenges

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.
This article collection contains several articles on the vital role that compressed air plays in manufacturing plants.