Remotely resettable electronic circuit breaker

The E-T-A ESX10-TC is a 12 V DC version of the 24 V ESX10-T and is designed for SCADA/RTU applications, providing protection for switch-mode power supplies and solar/battery-based systems.

09/19/2011


E-T-A expanded its line of electronic circuit protection products with the ESX10-TC, a 12 V dc version of the ESX10-T, 24 V dc product offering and is designed for SCADA/RTU applications – providing protection for 12 V dc switch-mode power supplies and solar/battery based systems.

The most unique feature of ESX10-TC, E-T-A said, is the ability to remotely reset the device from outside an enclosure. This can be accomplished via a simple momentary push button or from an output of an RTU or PLC controller. In RTU/SCADA applications, equipment is primarily located in remote unpopulated locations. The remote reset functionality reduces the need for field engineers to travel to sites to troubleshoot equipment – reducing the overall cost of equipment maintenance and downtime.

The ESX10-TC is available in fixed current ratings from 1 A to 10 A and provides selective load protection - ensuring exclusive disconnection of the current path in the event of an overload or short circuit in the field load device without compromising the dc 12 V power source (such as battery drain).

The ESX10-TC limits the short circuit current to 1.3 to 1.8 times rated current and disconnects 100 ms after the fault has been detected. Inrush peaks are tolerated from capacitive loads of more than 20,000 μF and is designed with an auxiliary output to provide individual alarm capabilities for critical process flow applications. This space-saving device has a width of only 12.5 mm and 80 mm in height and depth. Its low power consumption makes it ideally suited for battery-buffered dc 12 V applications, specifically in the solar industry.

The ESX10-TC is DIN rail ready and can be mounted either individually or in a group side-by-side with a simplistic bus bar system for +12 V dc and ground. It also uses the same screw terminals as its 24 V dc counterpart which allows up to a 10 mm² conductor to be wired directly to the device, this ensures reliable and safe wiring connections.

www.e-t-a.com 

E-T-A

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
The true cost of lubrication: Three keys to consider when evaluating oils; Plant Engineering Lubrication Guide; 11 ways to protect bearing assets; Is lubrication part of your KPIs?
Contract maintenance: 5 ways to keep things humming while keeping an eye on costs; Pneumatic systems; Energy monitoring; The sixth 'S' is safety
Transport your data: Supply chain information critical to operational excellence; High-voltage faults; Portable cooling; Safety automation isn't automatic
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Maintaining low data center PUE; Using eco mode in UPS systems; Commissioning electrical and power systems; Exploring dc power distribution alternatives
Synchronizing industrial Ethernet networks; Selecting protocol conversion gateways; Integrating HMIs with PLCs and PACs
Why manufacturers need to see energy in a different light: Current approaches to energy management yield quick savings, but leave plant managers searching for ways of improving on those early gains.

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.