In the midst of a facility expansion in March 2007, MVP Health Care (MVP), Rochester, N.Y., decided that a reliable mode of standby power was required to ensure smooth operations and to keep all of its clients’ medical records and information safely housed.

11/02/2010


In the midst of a facility expansion in March 2007, MVP Health Care (MVP), Rochester, N.Y., decided that a reliable mode of standby power was required to ensure smooth operations and to keep all of its clients’ medical records and information safely housed. MVP, a healthcare provider in Vermont, N.H., and N.Y. has been committed for 27 years to making a positive impact on the health and wellness of its customers. The need to keep medical records and information safe was a logical investment and consistent with the company’s mission. While there was an immediate need for a larger location, MVP also needed to allow room for future growth. The goal was that no matter how much the company grew, there would always be backup power protection should there be an outage due to the inclement weather that is typical of Rochester, especially during the winter months. When Generac Industrial Power dealer R.L. Kistler learned of MVP’s interest in standby power, sales engineer Rob Sweeney knew he had a system to satisfy its needs.

Based in Rochester, R.L. Kistler has been a Generac dealer since 2002, covering much of the upstate New York area including Buffalo and the state capital of Albany. Sweeney was approached for this project by engineer Mark Picard, owner of Picard Engineering, Rochester, who was originally looking for backup power that had either a single engine or a modular system; this was still up for debate.

“When Mark told me what they were looking for, I knew right away that the Generac Modular Power System (MPS) was the way for them to go. They had an immediate load demand of 1,100 kW and wanted a system that had the potential to reach 1,600 kW, if needed,” says Sweeney. “They were also in the market for a system that ran on natural gas rather than diesel due to storage limitations stemming from MVP’s metropolitan location and the fact that natural gas offered extended run times without concern for refueling. I told Mark he’d be hard-pressed to find a competitive system that would be able to not only meet their demands, but also be reasonably priced. After he had an opportunity to shop around, the job was ours.”

Installation with room to grow

R.L. Kistler administered the paralleled installation of 4 x 300 kW Generac natural gas generators in August 2008. Because MVP intended to grow over time, the company needed a system that was modular and did not need to be replaced every time it expanded. As the installation began, Sweeney wanted to make it as easy as possible for the building to add on to the four existing gensets as needed. “We installed a concrete pad designed to hold a maximum of six, 300-kW generators. So when the time comes to expand the system, there is room for two more 300-kW Generac MPS generators, making the placement less labor intensive,” says Sweeney. In addition to the versatility that comes with a Generac MPS, price was also a factor.

One digital control, one generator

In the past, the high cost of paralleling switchgear made the multiple-unit arrangement feasible only for expensive, high-end applications. If MVP had gone with a traditional paralleling approach, it would have had to use 14 to 20 controllers from five different manufacturers. However, the Generac MPS PowerManager control technology requires only one digital control per generator to control all generator functions: speed governing, voltage regulation, genset alarm and monitoring, synchronizing, load sharing, and protection—a much simpler and cost-saving approach.

Advanced microprocessors with high-speed, 32-bit digital electronics are integrated into the MPS controllers, providing paralleling capability and reducing equipment, maintenance, and installation costs. Constantly monitoring power flow, controlling transfer switch functions, and managing the operations of all connected generators are just a few of the features offered by the MPS controllers. The beauty of the Generac MPS system is that each genset backs up the others in the system, so critical loads receive state-of-the-art redundant protection, in addition to providing all the benefits of paralleled power generation in a simple, single-source system.

Looking to the future

Today, the Generac MPS system backs up three floors, one of which houses the main data center—a total of 50,400 sq ft. And MVP has no plans to stop there. “This year, we’ll be adding another 150 servers to our data center on the first floor and while we are appropriately sized right now, we have space to add two more 300 kW gensets and in time that’s exactly what we plan to do,” says Craig Solow, supervisor of Windows administration, MVP. “We could not be more pleased with the natural gas MPS system from Generac. Out of our 10 sites, the Rochester location is the only one that has a modular backup system, the rest are running on single systems, and I am confident that the Generac MPS system is the most secure. Since we installed the Generac MPS system, we’ve had a few outages, some planned, some unexpected, but whatever the case, the transition to standby power was seamless. The MPS system started right up and kept us operating at business as usual for the entire length of every outage. Most companies fear outages, and while we don’t look forward to them, we know that we’re covered.”

Information provided by Generac Power Systems Inc.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2015 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
2016 Product of the Year; Diagnose bearing failures; Asset performance management; Testing dust collector performance measures
Safety for 18 years, warehouse maintenance tips, Ethernet and the IIoT, GAMS 2016 recap
2016 Engineering Leaders Under 40; Future vision: Where is manufacturing headed?; Electrical distribution, redefined
SCADA at the junction, Managing risk through maintenance, Moving at the speed of data
Safety at every angle, Big Data's impact on operations, bridging the skills gap
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
Applying network redundancy; Overcoming loop tuning challenges; PID control and networks
Driving motor efficiency; Preventing arc flash in mission critical facilities; Integrating alternative power and existing electrical systems
Package boilers; Natural gas infrared heating; Thermal treasure; Standby generation; Natural gas supports green efforts

Annual Salary Survey

Before the calendar turned, 2016 already had the makings of a pivotal year for manufacturing, and for the world.

There were the big events for the year, including the United States as Partner Country at Hannover Messe in April and the 2016 International Manufacturing Technology Show in Chicago in September. There's also the matter of the U.S. presidential elections in November, which promise to shape policy in manufacturing for years to come.

But the year started with global economic turmoil, as a slowdown in Chinese manufacturing triggered a worldwide stock hiccup that sent values plummeting. The continued plunge in world oil prices has resulted in a slowdown in exploration and, by extension, the manufacture of exploration equipment.

Read more: 2015 Salary Survey

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.
This article collection contains several articles on the vital role of plant safety and offers advice on best practices.
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.
This article collection contains several articles on strategic maintenance and understanding all the parts of your plant.
click me