Factory floor visualization

Soapbox: When it comes to sharing information, the factory floor has simply not kept pace with the rest of the business world. There have been vast improvements in HMIs (human machine interfaces) over the years, but the majority of HMI and SCADA (supervisory control and data acquisition) systems are standalone applications, and often manual processes.


When it comes to sharing information, the factory floor has simply not kept pace with the rest of the business world. There have been vast improvements in HMIs (human machine interfaces) over the years, but the majority of HMI and SCADA (supervisory control and data acquisition) systems are standalone applications, and often manual processes. This is in sharp contrast to the office environment, which has fully embraced data sharing technologies like e-mail, instant messaging, MRP/ERP systems, office productivity suites, and electronic project tracking.


Why the difference? It’s all about performance and stability. While various HMI packages offer Web access or Web publishing today, the underlying technologies of most of these do not meet the needs of the factory floor. Inadequate software performance slows data sharing and remote HMI use on the factory floor—but it doesn't have to be that way.


The most straightforward way of publishing Web data is using standard HTML (hypertext markup language). This is the original language of the World Wide Web. While it works great for viewing static pages of data, it fails miserably when trying to view changing data or provide real-time control of a machine. The reason is that HTML is designed to be client-driven.


With HTML, the client browser is responsible for requesting new data, and there is no mechanism for the server to “push” new data to the client. To get real-time updates, the client must “poll” the server by requesting refreshes on a regular basis. Since this means resending an entire page of data, update frequency rates are severely limited. This makes it impractical for applications requiring instant alarm notification, real-time data monitoring, or interactive animations.


Another common option for remote monitoring and control is a class of technologies known as “screen scraping.” This is the approach taken by most remote HMI products. As the name implies, these technologies essentially scrape off the image on the server’s screen and transfer it to the client. The client machine then displays the server’s screen image, and transfers its own user input to the server. This lets the operator interact with the machine as if he or she were in front of it.


Screen scraping is used in many of today’s “Web published” HMIs and, while it does allow for remote access, it is not real-time and performance is a problem. Because so much data are being transferred, screen scraping requires high-speed connections, and it severely limits the number of clients.


Another common approach is to create a custom browser plug-in that is responsible for communicating with the server and transferring information to a remote thin client. If the program is designed well, this approach can solve the bandwidth problem by eliminating the need to poll for data and transferring only information that has changed. This approach also can allow remote operators to view different screens than what the server shows. In practice, however, these solutions are often overly complicated to set up and administer. They also require installing custom, and usually expensive, applications on every client system.


Off-the-shelf browser technologies such as Adobe Flash can solve these issues. More than 98% of all desktop Web browsers already have Adobe Flash installed on their systems (avoiding custom plug-in hassles), and Flash’s installed base ensures wide acceptance.


We decided to use Flash in our Interact Xpress and Parker Factory Display product lines to provide for a rich Internet experience through standard Web browsers. Flash provides all the advantages of a custom plug-in without the associated costs and hassles. And, it lets users get the “information anywhere” capabilities of remote Web access at about the same cost as a standalone HMI product.


With the capabilities of Flash technology, a Web browser can be embedded on a SCADA operator panel, thereby avoiding duplication of client HMI applications. In our estimation, up to 80% of the screens on a typical SCADA package already exist on the machine. Why duplicate them? This also means that Andon information is no longer restricted to the factory floor. Since the data are Web published, screens can be seen from any laptop or personal digital assistant anywhere in the world. All that is required is the proper security clearance, a network connection, and a Flash player-enabled browser.


Author Information

Andy Balderson is a product sales manager and Brent Meranda is an HMI software engineering manager with Parker’s Electromechanical Automation Division.

No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
Sister act: Building on their father's legacy, a new generation moves Bales Metal Surface Solutions forward; Meet the 2015 Engineering Leaders Under 40
2015 Mid-Year Report: Manufacturing's newest tool: In a digital age, digits will play a key role in the plant of the future; Ethernet certification; Mitigate harmonics; World class maintenance
2015 Lubrication Guide: Green and gold in lubrication: Environmentally friendly fluids and sealing systems offer a new perspective
Drilling for Big Data: Managing the flow of information; Big data drilldown series: Challenge and opportunity; OT to IT: Creating a circle of improvement; Industry loses best workers, again
Pipeline vulnerabilities? Securing hydrocarbon transit; Predictive analytics hit the mainstream; Dirty pipelines decrease flow, production—pig your line; Ensuring pipeline physical and cyber security
Cyber security attack: The threat is real; Hacking O&G control systems: Understanding the cyber risk; The active cyber defense cycle
Designing positive-energy buildings; Ensuring power quality; Complying with NFPA 110; Minimizing arc flash hazards
Building high availability into industrial computers; Of key metrics and myth busting; The truth about five common VFD myths
New industrial buildings: Greener, cleaner, leaner; New building designs for industry; Take a new look at absorption cooling; Offshored jobs start to come back

Annual Salary Survey

After almost a decade of uncertainty, the confidence of plant floor managers is soaring. Even with a number of challenges and while implementing new technologies, there is a renewed sense of optimism among plant managers about their business and their future.

The respondents to the 2014 Plant Engineering Salary Survey come from throughout the U.S. and serve a variety of industries, but they are uniform in their optimism about manufacturing. This year’s survey found 79% consider manufacturing a secure career. That’s up from 75% in 2013 and significantly higher than the 63% figure when Plant Engineering first started asking that question a decade ago.

Read more: 2014 Salary Survey: Confidence rises amid the challenges

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.