E-Stop buttons designed to enhance machine safety

While a risk assessment is a starting point to determine effective safety devices and methodologies, a key risk reduction component is the Emergency Stop

04/25/2013


The Emergency Stop is manually actuated by a single human action, effectively eliminating machine hazards. Courtesy: Banner EngineeringIn any industry, it is critical to produce quality products, fast and efficiently, while ensuring consistent results. To do this, facilities employ a variety of machine-based operations. Though efficient in use, these machines can present significant worker injury risks, ranging from soft-tissue injuries and disfigurement to amputation or even death.

To mitigate these risks, implementing a risk reduction strategy will improve workplace safety, enhance worker morale, and reduce liability. While a risk assessment is the best starting point to determine the most effective safety devices and methodologies, a key risk reduction component is the Emergency Stop. 

Understanding the E-stop 

The primary purpose of an Emergency Stop (E-stop) is to avert or reduce hazards or hazardous situations that could damage machinery/equipment or the work in process, and/or create increased risk of harm to individuals. The E-stop can employ several types of actuation devices, such as pushbuttons, rope/cable-pulls, push-bars/levers, etc., but all are manually actuated by a single human action. 

While E-Stop devices are not considered a true “safeguarding” device since they require a manual action to function, they are used as “complementary” equipment to augment required safeguarding practices and achieve acceptable risk. (See ANSI B11.0 General Requirements and Risk Assessment and ANSI B11.19 Performance Criteria for Safeguarding.) When required by the risk assessment—at a minimum—an E-Stop device must be continuously operable, clearly identified, clearly visible, and readily accessible.

E-Stops are typically located on the operator control panel and at locations around the machine or workcell that are up to 10 ft or less apart. NFPA 79 and IEC 60204-1 mandate that the E-Stop actuators must be red, and that pushbuttons must be on a yellow background and have a self-latching palm or mushroom-head style. The electrical contacts need to be a direct (positive) opening where the force of pushing the button opens the contacts.

Once the E-stop device is actuated, the emergency stop condition signal is sent to the machine control circuit. This immediately halts the dangerous movement/situation and removes power. Manually resetting the pushbutton, typically by twisting or pulling, must not initiate an automatic restart of the machine or other hazardous motion. To provide the minimum performance capabilities, E-stops should be designed to do the following:

  • Be initiated by a single human action
  • Override all other functions and operations in all other modes
  • Remove power to machine actuators quickly and without creating other hazards
  • Function as either a Category 0 or Category 1 stop, depending on the machine

A Category 0 stop immediately removes energy to the machine actuators; a “controlled” Category 1 stop leaves energy to the machine actuators to achieve the stop, at which time the energy is removed.

Innovative E-Stop technology

In an emergency situation, it is crucial that operators and others in the vicinity are able to stop hazardous machine motion or the process as quickly as possible. The swiftness relies on the E-Stop actuator being clearly identified, clearly visible, and readily accessible. The requirement for an E-Stop pushbutton to be red on a yellow background has gone a long way in improving “clearly identified” and “clearly visible.” Recently, identification and visibility have been brought to a new level with LED illumination.

New E-stop button technology combines the practicality of status indication with the safety inherent in emergency stop buttons in one, unique device. Two styles are on the market today: one with illumination in the pushbutton face and another with illumination in the enclosure base. The advantage of the illuminated base is generally more visibility via brighter indication and a 360-degree viewable surface.

Additionally, some illuminated E-stop buttons provide real-time status for workers on the plant floor. This can provide a solution to a common problem with E-Stop pushbuttons—identifying which button was pushed.

Illumination logic, whether provided externally or internally, allows workers to identify at a glance whether a button is armed or has been pushed. A pushed button can simply light up “red” or, in the case of an E-Stop with illuminated base, can indicate whether the button has been pushed (e.g., flashing red), the machine is stopped (e.g., solid red), or if the pushbutton is armed and the machine is ready to operate (e.g., yellow or green indication). Once the emergency situation has been rectified, users can easily identify and reset the button or buttons efficiently with minimal downtime. 

Diverse environments

To address “readily accessible” concerns and accommodate various applications, E-stop buttons are offered in enclosures for mounting remotely from the operator control panel in nearly any location or directly on a machine. With no assembly and quick-disconnect connectors, E-stop pushbuttons can be installed simply, quickly, and cost-effectively.

Machine safety is a cornerstone for productivity, profitability, and worker satisfaction. Taking precautions to minimize machine-related injuries is essential in today’s fast-paced, demanding industries. Therefore, implementing technologies, such as illuminated E-Stop pushbuttons, that deliver more information and enhanced machine performance can “augment” any risk reduction strategy.

Mike Carlson is safety products marketing manager for Banner Engineering.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2013 Leaders here.
The new control room: It's got all the bells and whistles - and alarms, too; Remote maintenance; Specifying VFDs
2014 forecast issue: To serve and to manufacture - Veterans will bring skill and discipline to the plant floor if we can find a way to get them there.
2013 Top Plant: Lincoln Electric Company, Cleveland, Ohio
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Bring focus to PLC programming: 5 things to avoid in putting your system together; Managing the DCS upgrade; PLM upgrade: a step-by-step approach
Balancing the bagging triangle; PID tuning improves process efficiency; Standardizing control room HMIs
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.