Drives optimize energy efficiency, reduce control room, panel space, cooling costs

Up to 68% smaller than previous generation drives, compact D-frame drives from Danfoss VLT Drives are optimized to deliver highly reliable performance in the 125 – 450 HP range while exhausting 90% of the drive-generated heat outside the enclosure via the backchannel.

Source: Danfoss VLT Drives

08/22/2012


Danfoss D-Frame VLT Drives are available in a power range from 125-450 hp (90-315 kW) and up to 68% smaller than previous generation D-Frame drives, new D-Frame drives require significantly less panel or wall space than previous models which were already among the smallest in their class. This reduces installation costs and increases installation flexibility. These drives also leverage back channel cooling to remove 90% of the heat generated by the drive, reducing both up front and ongoing costs and making them an ideal panel building solution.

 

“With ever-increasing demands for improved efficiency and reliability in drive technology, OEMs, panel builders and end users are looking for new technologies that can save energy, reduce costs and help simplify operations in a solution that will provide trouble-free operation for years,” said Greg Reichelt, Product Manager High Power Drives, North America. “The new D-Frame VLT drives deliver on each count. Not only are these drives among the smallest in their class, they also include an array of efficiency and safety enhancing options as standard features, enabling customers and end users to reduce both initial and ongoing operating costs.”

 

The new drives are available with IP20, IP21 (NEMA 1) or IP 54 (NEMA 12) enclosure protection ratings. For robust protection they also come standard with conformal coated printed circuit boards, which together with the optional heat sink access panel, help to extend drive lifetime and reliability. The new units can be factory-fitted with optional semiconductor fuses to further reduce installation costs. Additional factory-fitted basic input options, such as mains disconnect, contactor and circuit breaker, eliminate the need to install these basic options externally.

 

New D-Frame drives also use Danfoss’ unique and innovative back-channel cooling concept to keep electronics safely within optimal operation temperatures. The big advantage of back-channel cooling is that system installation and operating costs can be dramatically reduced.

 

“Using a ducted back-channel, air is allowed to pass over the unit’s heat sink with minimal air passing through the electronics area. This way 90% of the heat generated by the drive is exhausted directly outside of the enclosure, improving reliability and prolonging the lifetime of the unit. An IP54 (NEMA 12) seal between the back- channel cooling duct and the electronics area of the VLT drive helps to significantly reduce temperature rise and contamination of the electronic components,” explained Reichelt.

Danfoss provides energy-efficient solutions that help save energy and meet the challenge of climate change. Key competencies are cooling of food, air conditioning, control of electrical motors and heating in buildings – as well as solutions for renewable energy such as solar power. Danfoss also comprises Sauer-Danfoss that is among the world’s leading manufacturers of mobile hydraulics. The 77 year company employs 26,000 employees globally and has 140 sales companies globally.

www.danfossdrives.com



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results


Poll of the Week

What category most helps you select new products?
Recommendation from colleagues
Product of the Year winners
Supplier information
Trade show visit


Click Here for Poll Archives
Sponsored by:

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.