White paper: Optimizing drive systems for energy savings

Several areas should be considered when looking for potential opportunities to reduce energy consumption via the drive system.

William B. Gilbert, Siemens Energy and Automation

02/17/2012


Below is the abstract for a white paper on "Optimizing Drive Systems for Energy Savings." If you would like to download and read the full report please click here.


Abstract

Several areas should be considered when looking for potential opportunities to reduce energy consumption via the drive system.

The use of a common DC bus architecture as an alternative to individually powered AC drives will conserve energy by sharing the normally wasted regenerative energy from unwinds and other regenerating driven sections. In addition to sharing and saving energy, true common DC bus systems also conserve energy by eliminating many of the typical energy wasting system components.

Utilizing active front end (AFE) power sections to reduce system power factor and harmonics. Active front end power sections provide near-unity power factor and produce minimal harmonics. AFE’s can also compensate for the effects of poor power quality issues.

Reducing mechanical losses with direct drives, certain power transmission components can waste significant energy.

Optimizing drive sizes and tuning through mechatronic practices and tools. Oversized drives will use more power and adversely affect the system power factor. Poorly tuned drive systems can be a common source of energy waste.

Retrofitting older DC drive systems with more efficient AC drive systems.   AC Drive systems offer greater energy efficiency over older DC technology. Some AC drives can automatically reduce their magnetizing current under low load conditions

Utilizing energy efficient motors for across the line applications and AC drives in front of the motors in place of mechanical dampers and valves.


If you would like to download and read the full white paper on "Optimizing Drive Systems for Energy Savings" please click here.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.