The next big thing in data centers

We must keep on top of the latest trends and technologies to ensure that we provide high value to data center clients.

06/12/2012


Keith Lane, president and CEO of Lane Coburn & Assoc.The next “big thing” in the mission critical market will be evolution of data center infrastructure management (DCIM).

For data centers and other mission critical facilities, much of what we call DCIM today is comprised of separate discrete systems for electrical monitoring, airflow simulation, load and server tracking, and the native knowledge of data center operators.

Today’s data centers are no longer just a part of day-to-day business; they provide companies with a competitive advantage. DCIM can be leveraged to increase efficiency, utilization, and availability of data center assets.

While both IT and facilities have invested in technology resources to manage mission critical facilities, they typically do not work collaboratively to achieve the ultimate promise of DCIM.

The main components of a good DCIM system include the following:

  • Real-time data tracking to determine the true capacity of the data center “real time”
  • Identifying the important interdependencies between logic and physical layers
  • Holistic management capabilities
  • Visibility of IT and facility infrastructure
  • Good visual views and guidance on design changes
  • Change management.

The cutting-edge and future of DCIM embraces all of these separate pieces of information and integrates them into a single integrator. The DCIM systems available today can allow the data center operator to actually use critical separate pieces of information for the following functions:

  • Load monitoring
  • Asset management
  • Load balancing
  • Power usage effectiveness (PUE) analysis
  • Future scenario analysis
  • Dependency analysis
  • Failure and recovery analysis
  • Workflow management
  • Security.

There needs to be a closer association between designers, facility managers, and IT personnel in order to reap the benefits of true DCIM. Data center strategies in the past were fairly simple. Mission critical facilities’ lifecycles are approximately 15 to 20 years. As IT and business strategies evolved during this time, data center infrastructure management has historically been a slow-moving objects.

Good planning software tools typically perform the following:

  • Display the pending impact of moves, adds, and changes
  • Give graphic location of IT equipment in the rack
  • Make recommendations for future racks and servers
  • Simulate the failure of power and cooling components
  • Provide management of rack and floor tile weights
  • Simulate cooling scenarios with computational fluid dynamics (CFD).

DCIM includes the management of IT systems. These components include servers, network systems, and storage. The critical management tools include inventory management, asset management, change tracking, workflow tracking, dependency analysis, feasibility analysis of anticipated facility modifications, and future scenario analysis.

The traditional method of planning and crisis prevention has historically been based on manual calculations and tribal knowledge and is not effective or reliable. DCIM is a great modeling tool for possible failures in the data center and can simulate how the data center will react to electrical and/or mechanical component failure and the interdependencies between the systems.

A good, well-integrated DCIM system can allow mission critical facility managers to reduce energy usage and costs, and PUE.

As mission critical facility engineers and designers, we must keep abreast of the latest trends and technologies in order to ensure that we provide the most value to our clients.


Lane is president and CEO of Lane Coburn & Assoc.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2013 Leaders here.
The new control room: It's got all the bells and whistles - and alarms, too; Remote maintenance; Specifying VFDs
2014 forecast issue: To serve and to manufacture - Veterans will bring skill and discipline to the plant floor if we can find a way to get them there.
2013 Top Plant: Lincoln Electric Company, Cleveland, Ohio
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Bring focus to PLC programming: 5 things to avoid in putting your system together; Managing the DCS upgrade; PLM upgrade: a step-by-step approach
Balancing the bagging triangle; PID tuning improves process efficiency; Standardizing control room HMIs
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.