Rugged, 6-way secure virtual machine server

General Micro Systems, Inc., designer and manufacturer of embedded computing products for defense, aerospace and compute-intensive applications has introduced the “Zeus” (SCZ91X), a “super-server” that revolutionizes client-server architecture products available for military systems.

04/27/2012


Zeus (SZC91X) Compact, Rugged, Six-way Secure Virtual Machine Server, Courtesy: GMS

General Micro Systems Inc. (GMS), designer and manufacturer of embedded computing products for defense, aerospace and compute-intensive applications, and the leader in high-end Intel processors since 1986, has Introduced the “Zeus” (SCZ91X), a “super-server” that revolutionizes client-server architecture products available for military systems. The Zeus represents an eight-fold performance improvement over any current products and the unprecedented security of data and operations through a “Trusted Computing Platform.”

Zeus (SZC91X) Compact, Rugged, Six-way Secure Virtual Machine Server, Courtesy: GMS
Responding to military and industry needs for a server that can run multiple applications on different OS simultaneously without interrupting the main processor or operating system, the Zeus replaces dedicated processing systems or single level servers – and through a Hypervisor or Virtual Machine Manager – can concurrently run numerous, independent operating systems.

Handling it all through a Westmere-EP processor – the most powerful Xeon 5600 processor from Intel -- the Zeus is based on six physical CPU cores, with hyperthreading for a total of 12 cores. Each core operates at up to 2.4 GHz, with the ability to run in TurboBoost mode up to 2.67 GHz. Each guest, as well as the core, is assured uninterrupted operation through the integration of the Westmere-EP with its fully integrated memory controller and massive high-speed memory.

The Zeus can have up to 96 Gbytes of RAM organized in three banks. Each RAM bank consists of two DDR-3 DIMM arrays with Error Correcting Code (ECC). The ECC RAM supports up to 1333 Mega Transfers per Second (MTS) to/from the CPU, which is the fastest random access memory rate per second in the industry.

Accommodating the widest array of ultra-high-speed I/O devices, the Zeus comprises a host CPU I/O and six Virtual Machine I/O (VMIO) sites, several of which are available as standards. Two removable 2.5-in. SSD drives are supported on the host side, as well as one PMC/XMC site and one mSATA drive for a local boot device.

Configured as “share nothing” architecture, each VMIO site is independent and is connected to the host CPU via PCI-Express lanes only. (If one I/O input is struck by lightning, for example, all the other channels are unaffected.) All I/O transactions are fully monitored through the TPM/TXT/VT-x security engines to assure access is authorized by the host CPU. VMIO connections to the Zeus are through 38999 military connectors.

Zeus (SZC91X) Compact, Rugged, Six-way Secure Virtual Machine Server, Courtesy: GMS

While GMS has engineered the Zeus for highest possible performance in a rugged server, it also ensures optimum security through its “Trusted Computing Platform.” At the philosophy’s center is the “Trusted Platform Module,” (TPM) a hardware-based specification that can be used to encrypt or scramble data, enabling the “sealing” of applications and even an entire operating system. The TPM can also encrypt the system’s configuration, allowing it to pick up on any unsecure devices, and block the computer from starting if one is detected.

“Some branches of the U.S. government are now requiring TPMs on any new systems purchased. GMS is behind this 100%, since we are committed to protecting the data and operations owned by our customers,” says Ben Sharfi, CEO of GMS. “It is absolutely critical that each and every time a system is turned on, that nothing has changed since its last use. This security is provided in the Zeus – making it a true ‘Trusted Computing Platform.’”

The first fully rugged server in the industry, the Zeus is designed to provide the highest level of server-class performance possible in a ruggedized, conduction-cooled system, operating -40 C to +85 C at full load.  With conformal coating, the Zeus is unaffected by salt, fog, humidity, fungus and rain; is shock-proof; vibration-proof; and engineered for altitude, all per Mil-Std 810G.

The Zeus supports the most common Hypervisors by VMware, WindRiver and Microsoft, and can be shipped with operating systems such as Microsoft Windows 7, Linux and VXWorks already installed.

High resolution images and datasheet available.

www.gms4sbc.com 



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2013 Leaders here.
The new control room: It's got all the bells and whistles - and alarms, too; Remote maintenance; Specifying VFDs
2014 forecast issue: To serve and to manufacture - Veterans will bring skill and discipline to the plant floor if we can find a way to get them there.
2013 Top Plant: Lincoln Electric Company, Cleveland, Ohio
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Bring focus to PLC programming: 5 things to avoid in putting your system together; Managing the DCS upgrade; PLM upgrade: a step-by-step approach
Balancing the bagging triangle; PID tuning improves process efficiency; Standardizing control room HMIs
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.