Making power more efficiently

Improving control of feedwater heaters improves heat transfer and reduces operating cost.

01/29/2013


It is a common practice in the electric utility industry to utilize multiple stages of shell and tube heaters to preheat feedwater going to the boiler. The challenge has always been transferring as much heat as possible from the steam inside the shell to the water in the tubes. The mechanical design of the heaters helps this by providing baffles to prevent steam from exiting the heater rather than condensing. Heaters cascade from the highest shell pressure being the last in the train to the lowest being the first. There is also one heater called a deaerator that is an open heater between the low-pressure and high-pressure closed heaters where steam mixes with feedwater and any entrained air is removed. The steam for heating feedwater comes from extraction stages of the turbine and from the drain of the next higher-pressure heater.

The mechanical design of the heaters helps this by providing baffles to prevent steam from exiting the heater rather than condensing. Heaters cascade from the highest shell pressure being the last in the train to the lowest being the first. At first blush, this seems to be a mainly mechanical, self-regulating system, but there are control challenges. First, this is a highly interactive system with the pressure in the shell being a function of the extraction stage of the turbine, the rate of condensation, and the rate of what’s coming from the next higher heater’s drain. The feedwater’s temperature increase is dependent on absorbing heat being released by the condensing steam, which is a function of the level in the heater shell. The more tubing surface area exposed to steam, the more heat can be transferred. A flooded heater will transfer very little heat to the feedwater, and an uncovered drain will let steam pass without condensing fully, so controlling feedwater level in the heater shell is critical.

One additional issue is that not all of the steam is coming from the turbine extraction. Some comes from the drain of the next higher heater. As the heater drains, its condensate passes through a control valve where it flashes back to steam on its way down to the next heater. The control valve must not allow pressure in the drain line to drop below the pressure of the turbine extraction feeding the heater. If the drain valve outlet pressure gets too low, the heater being drained will back up. This is an application where valve sizing and performance is critical. Now multiply these complexities by six or seven stages of heating, and you begin to get the magnitude of the control problem.

Control engineers today have some arrows in their quivers that weren’t available when I first started out. For one thing, controllers today have the ability to do their own internal efficiency calculations. For example, a drop in the efficiency of a heater can indicate fouling in the tubes. In older systems, a problem like that would only have showed up after progressing to the point of being a major issue. Some current DCSs have built-in function block libraries covering thermodynamic properties of water and steam, so doing a real-time enthalpy balance around a heater becomes trivial. We can build a multiple-in-multiple-out (MIMO) predictive model running in the controller that can coordinate a group of operating heaters as a set rather than individual units to address interactivity. The bottom line is, with these advances, we can improve on efficiency gains from using heater systems and maintain them better over time.

What other areas of efficiency improvement have you seen?

This post was written by Bruce Brandt, PE, DeltaV Technology Leader at MAVERICK Technologies, a leading system integrator providing industrial automation, operational support and control systems engineering services in the manufacturing and process industries. MAVERICK delivers expertise and consulting in a wide variety of areas including industrial automation controls, distributed control systems, manufacturing execution systems, operational strategy, and business process optimization. The company provides a full range of automation and controls services – ranging from PID controller tuning and HMI programming to serving as a main automation contractor. Additionally MAVERICK offers industrial and technical staffing services, placing on-site automation, instrumentation and controls engineers.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
The true cost of lubrication: Three keys to consider when evaluating oils; Plant Engineering Lubrication Guide; 11 ways to protect bearing assets; Is lubrication part of your KPIs?
Contract maintenance: 5 ways to keep things humming while keeping an eye on costs; Pneumatic systems; Energy monitoring; The sixth 'S' is safety
Transport your data: Supply chain information critical to operational excellence; High-voltage faults; Portable cooling; Safety automation isn't automatic
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Maintaining low data center PUE; Using eco mode in UPS systems; Commissioning electrical and power systems; Exploring dc power distribution alternatives
Synchronizing industrial Ethernet networks; Selecting protocol conversion gateways; Integrating HMIs with PLCs and PACs
Why manufacturers need to see energy in a different light: Current approaches to energy management yield quick savings, but leave plant managers searching for ways of improving on those early gains.

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.