Load-bank testing ensures performance, reliability

Maintaining genset performance, health, and reliability depends on performing regularly scheduled load-bank testing.

11/20/2012


Load-bank tests assure facility managers that their generators will perform well at 100% of their nameplate rating. The absence of regular load-bank testing dramatically increases the potential risk of generator failure during an emergency. Load-bank testing should be a regular part of a generator maintenance program to avoid mechanical failure caused by extreme stress on the engine and other components when the generator is used in a power outage (see Figure 1).Figure 1: This technician is performing voltage checks during genset testing with a portable load bank. Courtesy: DynaTech It also helps maintain vital engine system parameters such as oil pressure and coolant temperature while preventing wet stacking and carbon buildup.

Wet stacking occurs when unburned fuel accumulates in the exhaust system due to running the generator at less than full load and therefore not producing enough heat to burn off the excess fuel. This accumulation can reduce engine lifecycle and efficiency by fouling the fuel injectors, engine valves, and exhaust system. If the correct mixture of fuel and air is not maintained, the engine will not operate at its highest level and will deliver less power.

As with wet stacking, carbon buildup typically occurs when the generator’s engine runs at less than full load, producing insufficient heat to remove the buildup. If carbon buildup continues unchecked, over time the piston rings can seize, which could allow the superheated fuel/air mixture to sneak past the rings and scorch the sides of the pistons (see Figure 2).

Load-bank basics

A load bank applies a stable controllable electrical load on a generator. It can be permanent or portable, can accommodate ac or dc, and can range from a few kW to multiple MW. Most load-bank units have an internal fan that cools the resistive elements and discharges the high temperature air away from the unit. It is very important to properly position the load-bank unit away from combustible material and to ensure that it is operated in a well-ventilated environment to keep it—and the generator—from overheating.

Table 1: Load Bank Test LogThe two types of load-bank testing methods are resistive and reactive. Resistive is the most common field testing method because it encompasses the full kW rating of the generator and the engine systems, such as the cooling, exhaust, and fuel delivery system. Reactive testing is typically performed at the genset factory to test kVA ratings.

Load-bank testing schedule

Generators must be able to go from a cold start to a full load in a matter of seconds. Just as the human body needs to be stretched and warmed up before a 100-yard sprint, the generator must be exercised at 30% load for at least 30 min monthly. Testing at this level and frequency keeps engine parts lubricated, prevents oxidation of electrical contacts, consumes fuel before it deteriorates, and enables reliable engine starting.

An annual load-bank test should be performed at 100% of the generator’s kW capacity for a minimum of 1 hr, or loaded to the minimum engine exhaust temperature recommended by the engine manufacturer. The load-bank test should be performed by stepping up the load at certain time intervals (see Table 1).

Testing tips

One of the goals of load-bank testing is to discover problems in a controlled situation rather than during an actual power failure. The following list suggests tips for discovering problems safely:

· When performing load-bank tests, be prepared for system failure, unexpected results, or the worst-case scenario.

· A backup generator should be in place at mission critical sites such as healthcare facilities with patients on life support, or any facility that absolutely cannot afford a power interruption.

· For facilities that are not mission critical, testing should occur during hours that can most easily manage a power failure—just in case.

· Ensure the generator is disconnected from the facility to prevent overloading.

· When testing, look for loose connections, leaks, and abnormal performance.

· An engine that emits black exhaust during the testing period typically is running at a high enough temperature to burn away the carbon buildup and the fuel in the exhaust system. However, if the smoke does not clear before the testing is completed, engine repairs may be necessary. Extensive smoke is most often caused by rings that have never seated properly, by a fuel pump that must be rebuilt, or by bad fuel.Figure 2: This photo shows the results of progressive carbon buildup. Over time, carbon buildup caused the rings to seize, resulting in a complete engine meltdown and a critical failure. Courtesy: DynaTech

· Other common occurrences during testing include high cooling system temperature and low oil pressure. High temperature can be due to a faulty thermostat or a restriction in the system. Low oil pressure can be the result of an oil pump in need of repair or an indication of excessive engine wear. 

Conclusion

Load-bank testing should be incorporated into a regular generator maintenance schedule to ensure peak performance and maximum reliability. Testing allows the operator to determine if the genset can run at its full kW capacity (without the risk of having to use the facility’s electrical distribution system and its load). Regularly-scheduled load-bank testing removes unused fuel in the exhaust and carbon buildup in the engine that can damage the genset and compromise its ability to produce emergency power when it’s needed most.


Ballas is the sales team leader for DynaTech, a generator sales and service company in Lebanon, Pa. He has experience creating and selling preventive maintenance agreements for air compressor and emergency generator systems.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2015 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
World-class maintenance: The three keys to success - Deploy people, process and technology; 2016 Lubrication Guide; Why hydraulic systems get hot
Your leaks start here: Take a disciplined approach with your hydraulic system; U.S. presence at Hannover Messe a rousing success
Hannover Messe 2016: Taking hold of the future - Partner Country status spotlights U.S. manufacturing; Honoring manufacturing excellence: The 2015 Product of the Year Winners
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
Getting to the bottom of subsea repairs: Older pipelines need more attention, and operators need a repair strategy; OTC preview; Offshore production difficult - and crucial
Digital oilfields: Integrated HMI/SCADA systems enable smarter data acquisition; Real-world impact of simulation; Electric actuator technology prospers in production fields
Improving flowmeter calibration; Selecting flowmeters for natural gas; Case study: Streamlining assembly systems using PC-based control; CLPM: Improving process efficiency, throughput
Putting COPS into context; Designing medium-voltage electrical systems; Planning and designing resilient, efficient data centers; The nine steps of designing generator fuel systems
Warehouse winter comfort: The HTHV solution; Cooling with natural gas; Plastics industry booming

Annual Salary Survey

Before the calendar turned, 2016 already had the makings of a pivotal year for manufacturing, and for the world.

There were the big events for the year, including the United States as Partner Country at Hannover Messe in April and the 2016 International Manufacturing Technology Show in Chicago in September. There's also the matter of the U.S. presidential elections in November, which promise to shape policy in manufacturing for years to come.

But the year started with global economic turmoil, as a slowdown in Chinese manufacturing triggered a worldwide stock hiccup that sent values plummeting. The continued plunge in world oil prices has resulted in a slowdown in exploration and, by extension, the manufacture of exploration equipment.

Read more: 2015 Salary Survey

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.
This article collection contains several articles on the vital role that compressed air plays in manufacturing plants.
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.
This article collection contains several articles on strategic maintenance and understanding all the parts of your plant.
click me