Level switch suitable for monitoring liquid levels in safety applications up to SIL3

E+H introduces Liquiphant FailSafe FTL8x point level switch and two-channel switching unit.

12/19/2012


E+H introduces Liquiphant FailSafe FTL8x point level switch and two-channel switching unit.Endress+Hauser has introduced its Liquiphant FailSafe FTL8x series of point level switches. The level switches have two relay outputs, a 4-20 mA output that connects to a failsafe switching unit with a two-channel output, safety contacts, and a safety locking function.

The 4-20 mA output can be connected directly to a safety PLC or similar system for min and max safety applications up to SIL3. The 4-20 mA signal jumps from high to low current when the min or max point level is reached for reliable detection by the safety system. In addition, a permanent live signal of 0.25 Hz is superimposed on the sensor output to indicate the sensor is operating in a good state. The level switch meets SIL3 requirements in accordance with IEC 61508, IEC 61511-1, ISA 84-1 and DIN EN ISO 13849.

For high reliability, built-in diagnostics monitor the tuning fork-type sensor for damage, corrosion, material buildup, and mechanical blocking. If a problem occurs, the live signal changes to notify the operator, a fault relay sends a signal to an annunciator or PLC, and a combination of three LEDs on the housing indicate the problem so that the switch can be cleaned, repaired, or replaced prior to failure.

These switches can be used for point level detection in liquids from -76 to 536 °F (-60 to 280 °C), at pressures up to 1,450 psi (100 bar), viscosity up to 10,000 mPa-s, and densities from 0.4 to 2.0 g/cm3. The FTL8x can also be used in highly corrosive media. Tuning fork sensors are available in 316L or 318L stainless steel with Alloy C22 plating, and the other wetted parts are available with Alloy C22 plating, or ECTFE or PFA coatings for use in aggressive liquids. A choice of polyester, stainless steel, or aluminum housings for the electronics are available, with or without a sight glass.

For North America, these switches are designed as either single seal or dual seal devices with an alarm in accordance with ANSI/ISA 12.27.01. This means that the user does need to install an external secondary process seal which is required in ANSI/NFPA 70 (NEC) and CSA 22.1 (CEC). These devices comply with installation practice in North America and enable very safe, low-cost installation in pressurized applications with hazardous media.

The FTL8x switches meet ATEX, CSA, FM, UL, IEC ex, NEPSI, and TIIS requirements for use in non-hazardous areas. Special models are available for use in hazardous areas or applications with high pressures.

Endress+Hauser

www.us.endress.com

Edited by Peter Welander, pwelander@cfemedia.com



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.