I/O Modules: Product research and advice from Control Engineering subscribers

I/O module research shows that Control Engineering readers want modular, easy-to-use, rugged I/O, with many analog, digital, and networking options. Manufacturers say new I/O modules pack in those features. See more results, advice, products. NEW: PDF research report attached April 2.

02/01/2010


LINKS

More on I/O modules from Control Engineering , below:

-I/O module advice from survey respondents, vendors

- Respondent vendor, network protocol preferences - Control Engineering research report- PDF format

-I/O products & photos: Banner Engineering, Beckhoff Automation, Emerson Process Management, GE Intelligent Platforms, Invensys, Pilz, Turck, Yokogawa, and others.

Leave your view: What are your most significant I/O module-related issues? Please use the TalkBack feature at the bottom of the page.

I/O connectivity: Mostly PLCs

Control Engineering readers offered advice about I/O modules trends, use and capabilities in an online survey emailed on Jan. 7 to subscribers of the Control Engineering System Integration, Machine Control, and Process and Advanced Control eNewsletters.
By Jan. 11, 506 survey respondents represented a “next project” I/O count of more than 389,850 I/O points, an average of more than 770 I/O points each.
Most-needed I/O module features are digital and analog capabilities, and a design that plugs into a base or rack, snaps on more points, and can mix digital and analog. Also popular are capabilities for use within an enclosure, diagnostics, optical isolation, and easy expansion. Finding the right mixture of discrete, analog, and high speed I/O for specific applications, within budget, is a key challenge, agreed Jeff Payne, PLC, I/O and PC control product manager for AutomationDirect. Payne said vendors offer high I/O density of 32 and 64 points. Tighter designs save users’ money, Payne says.

I/O module: Leading features


 

In one example, Ingersoll CM Systems Inc.’s next generation deep fillet rolling machine saved 60% in costs compared to previous I/O modules, said Gary Munger, Ingersoll controls engineering manager. Savings came with fewer machine components and use of more economical Balluff IO-Link hubs. Fewer components also reduced the possibility of failures, Munger said.

 

Smart I/O modules

I/O module vendor loyalty

Programmable logic controllers account for most I/O connections, survey respondents said, more than three times the next largest connection, a distributed control system (DCS) or process automation system (PAS). Vendors have responded with wide-ranging connection capabilities. Omega Engineering’s Universal Remote I/O Modules connect to any PLC, the company says, offering up to 31 I/O modules daisy-chained per RS-485 link. They’re DIN-rail mountable, have optical isolation, and, at 0.69-in. x 3.94-in. x 4.72-in. (17.5 x 100 x 120 mm), can fit in small panels.

 

Survey respondents said industrial Ethernet and Ethernet connections account for more than half of network protocols used, followed by fieldbus, device-level, sensor-level, and wireless networks. Wireless designs are also said to resolve other issues.

 

Simatic ET 200pro IWLAN from Siemens Industry Inc. saves significant communication cabling and installation costs with wireless connectivity from any distributed I/O station and modules. The rugged IP67-rated design can be machine-mounted, without an electrical enclosure, Siemens says.

 

Nearly one-third (30%) of respondents said they use I/O modules with embedded intelligence to replace another controller. New I/O offerings for Eaton Logic Controllers (ELC) have smart I/O adapter modules that enable distributed I/O with limited local logic control. ELC distributed I/O communicate via EtherNet/IP and Modbus TCP Ethernet protocols, Modbus RS-485, and DeviceNet.

 

Opto 22 Snap Tex jacketed, pre-wired cables connect modules to field devices, terminal strips, and breakout boards.

Opto 22 Snap Tex jacketed, pre-wired cables connect modules to field devices, terminal strips, and breakout boards.

Phoenix Contact Busable 900 MHz radio provides simple I/O data connection, part of the Trusted Wireless Ethernet (TWE) industrial wireless portfolio.

Phoenix Contact Busable 900 MHz radio provides simple I/O data connection, part of the Trusted Wireless Ethernet (TWE) industrial wireless portfolio.

National Instruments cRIO-9022 Real-Time Controller uses an NI 9144 chassis to expand I/O module selection beyond 8 slots.

National Instruments cRIO-9022 Real-Time Controller uses an NI 9144 chassis to expand I/O module selection beyond 8 slots.

Write-in advice: Plan ahead...

Respondent write-in advice covered vendors, price, quality, lifecycle, networks, power and grounding, testing, and more. Respondents said to involve the owner early during the selection process; keep it simple; and leave room for spare I/O and slots. Develop standards for wiring and tagging wires, another said, and look at conversion rates to ensure they match control requirements. Look for distributed capabilities to place the I/O close to point of use and minimize installation and commissioning time.

 

What networks do you need your I/O systems to support?

Check all that apply. Base: 505 replied.

% / Protocol type / No. responses

62% Industrial Ethernet protocol 316
51% Ethernet protocol 259
39% Fieldbus protocol 196
32% Device protocol 163
24% Wireless protocol 119
18% Sensor-level protocol 91

Update: Due to a spreadsheet oversight, the print edition listed wireless response at 57, about 11%. Actual was 119 respondents, about 24%.

Source: Control Engineering research

 

Size of next I/O project

 

Study usage, location, customer requirements and future expansion plans. When sizing, determine how the finished control project should look in a drawing, identify physical points, separate by point type and signal used, compare with available points, and add necessary control hardware to connect the rest of the points.

 

Regarding networking and diagnostics, the biggest issue, said one respondent, is “the addressing between the I/O and the attached device. It seems that almost every vendor has its own addressing scheme. Use care and look into compatibility and ease of communication between devices.”

 

Remote I/O has come a long way for simplicity of configuration, update speed (now in real time), and cost effectiveness. Do research and take advantage of the new protocols, especially Ethernet-based ones, another said. Pressing I/O module-related issues are tied to protocol compatibility, ability of a node to multiple I/O types, and I/O module sizes, agreed Charlie Norz, product manager, Wago-I/O-System. Some products communicate in more than 16 protocols, Norz said, and save space inside machines.

 

 

 

Allen-Bradley 1762 I/O modules from Rockwell Automation expand connections to MicroLogix 1100, MicroLogix 1200 and MicroLogix 1400 controllers.

Allen-Bradley 1762 I/O modules from Rockwell Automation expand connections to MicroLogix 1100, MicroLogix 1200 and MicroLogix 1400 controllers.

On lifecycle issues, respondents said to leave room for expansion later and check how long current models will be in production and have support. Also ensure application engineering support and documentation are in the local language. A broad choice of I/Os is preferred. International standard programming, IEC-61131-3, is “very preferred.” ABB says its AC500-eCo I/O modules are easy to maintain, have a wide range of expansion modules, and the related controller uses IEC 61131-3.

 

 

Schneider Electric Modicon M340 PAC has discrete high-density I/O modules for up to 64 channels per module; analog I/O has up to 8 channels per module.

Schneider Electric Modicon M340 PAC has discrete high-density I/O modules for up to 64 channels per module; analog I/O has up to 8 channels per module.

Regarding power and grounding, noise problems can be avoided by using linear power supplies in lieu of switching power supplies. I/O should be hot swappable, not require downloads after connection, have channel-to-channel isolation, be G3 compatible, and have less power dissipation. “Along with isolation to remove ground loops,” said Bill McGovern, national sales manager, Dataforth Corp., input protection guards against over-voltages, while noise filtering serves to remove unwanted frequencies from I/O signals.

Honeywell Series C I/O has sleek styling for smaller footprint, easier installation and maintenance, longer life, and redundancy, if needed.

Honeywell Series C I/O has sleek styling for smaller footprint, easier installation and maintenance, longer life, and redundancy, if needed.

More on I/O modules from Control Engineering :
- Balluff-I-O hubs save machine builder 60%: Balluff IO-Link ;
- Banner-Wireless Banner Engineering working with Nivis to offer ISA100, WirelessHART ;
- Beckhoff-IO terminal EtherCAT interface for RTD temperature sensors ;
- Emerson - Updated control system rethinks field device connectivity and human interface ;
- GE Intelligent Platforms TranSphere TS Wireless I-O ;
- Invensys-Intrinsically safe I-O subsystem simplifies hazardous area ;
- Machine builder wins control panel design contest 60% less space, 30% less wiring ;
- Pilz - BMW uses Pilz decentralized I-O system, PSSuniversal ;
- Turck - RFID slice Turck BL67 modular distributed I-O system has a Simple RFID (RFID-S) ;
- Weidmuller-Wireless connectivity line ; and
- Yokogawa-Controllers DAQstation anniversary charts evolution of chart recorder - external I/O modules .

Also read:

- ABB AC500-eCo I/O modules can grow with the application , are easy to maintain, and offer a wide range of expansion modules, basic to advanced.

- I/O modules: Find the right mix, says AutomationDirect - I/O buyers are challenged to find the right mix of discrete, analog, and high speed I/O modules and remain within budget, company says.

- Dataforth DSCA DIN-rail mount isolated analog signal conditioners : Morethan 370 models of Dataforth DSCA isolated analog DIN rail mount signalconditioning modules are said to provide Dataforth Instrument Classperformance, outstanding accuracy, 3-way isolation, and pluggable screwterminal disconnects to simplify wiring and maintenance.

- Eaton Logic Controller input/output adapter - Eaton announces new I/O and I/O adapter offerings for Eaton Logic Controllers (ELC).

- Honeywell Series C I/O leverages the success and experience gained with port-mapped I/O to produce a unique design, the company says.

- National Instruments: 3 distributed I/O hardware platforms - Deterministic Ethernet Expansion Chassis, Ethernet/Serial Expansion Chassis, and Wireless and Ethernet Data Acquisition.

- Omega Engineering Universal Remote I/O Modules - HE359 Series provideS remote I/O for programmable logic controllers (PLCs); the application is no longer dependent on controller choice.

- I/O modules should be high density, easy to wire and configure, and reliable: Opto 22 - Opto 22 says density, ease of wiring, reliability, and auto-recognition setup software are must-have I/O module features.

- Phoenix Contact calls Axioline‘world's fastest I/O system' - Slow I/O? Blending Ethernet technology with terminal blocks, Phoenix Contact created the fastest available I/O speed, the company said at the Axioline I/O system introduction.

- Applications, lifecycle are I/O concerns, Rockwell Automation says - Resolving application-related issues and total cost of ownership are among customers' I/O-related issues, says Rockwell Automation.

- Keeping a low profile and being dense is OK, if you're an I/O module - Schneider Electric says I/O modules need to take up little space in the cabinet and offer a wide variety of voltage and current values to fit application needs. Distributed I/O on a machine can reduce wiring costs.

- Protocol compatibility, multiple I/O types : Wago - I/O module compatibility, ability of a node to accommodate multiple I/O types, and I/O module size, are important I/O topics, says Wago.

More graphics, research results on I/O Modules

Control Engineering Research Report: 2010 February I/O Modules offers more graphics and survey information not published in this article.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2015 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
2016 Engineering Leaders Under 40; Future vision: Where is manufacturing headed?; Electrical distribution, redefined
Strategic outsourcing delivers efficiency; Sleeve bearing clearance; Causes of water hammer; Improve air quality; Maintenance safety; GAMS preview
World-class maintenance: The three keys to success - Deploy people, process and technology; 2016 Lubrication Guide; Why hydraulic systems get hot
Flexible offshore fire protection; Big Data's impact on operations; Bridging the skills gap; Identifying security risks
The digital oilfield: Utilizing Big Data can yield big savings; Virtualization a real solution; Tracking SIS performance
Getting to the bottom of subsea repairs: Older pipelines need more attention, and operators need a repair strategy; OTC preview; Offshore production difficult - and crucial
Applying network redundancy; Overcoming loop tuning challenges; PID control and networks
Driving motor efficiency; Preventing arc flash in mission critical facilities; Integrating alternative power and existing electrical systems
Package boilers; Natural gas infrared heating; Thermal treasure; Standby generation; Natural gas supports green efforts

Annual Salary Survey

Before the calendar turned, 2016 already had the makings of a pivotal year for manufacturing, and for the world.

There were the big events for the year, including the United States as Partner Country at Hannover Messe in April and the 2016 International Manufacturing Technology Show in Chicago in September. There's also the matter of the U.S. presidential elections in November, which promise to shape policy in manufacturing for years to come.

But the year started with global economic turmoil, as a slowdown in Chinese manufacturing triggered a worldwide stock hiccup that sent values plummeting. The continued plunge in world oil prices has resulted in a slowdown in exploration and, by extension, the manufacture of exploration equipment.

Read more: 2015 Salary Survey

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.
This article collection contains several articles on the vital role that compressed air plays in manufacturing plants.
This article collection contains several articles on the Industrial Internet of Things (IIoT) and how it is transforming manufacturing.
This article collection contains several articles on strategic maintenance and understanding all the parts of your plant.
click me