GE will have Arc Vault system ready for summer delivery

GE will deliver the first Arc Vault system in the fourth quarter of 2010, earlier than originally planned, because of what the company said was “the overwhelming feedback received from customers and the expected demand.”

04/01/2010


GE will deliver the first Arc Vault system in the fourth quarter of 2010, earlier than originally planned, because of what the company said was “the overwhelming feedback received from customers and the expected demand.”

A new option will allow the Arc Vault system to be retrofitted onto both GE and non-GE low voltage switchboards, switchgear and motor control centers to expand its application for most existing facilities.

 

“We received a terrific response to our presentation and demonstration at the 2009 IEEE IAS (Industry Applications Society) Petroleum and Chemical Industry Technical Conference, in Anaheim,” said Paul Foody, general manager, product management for GE Energy’s electrical distribution business. “Since then we’ve been contacted by many customers requesting more information so we have decided to speed up the first delivery of the system to meet the expected demand.”

 

The arc fault protection technology will stop an arcing fault in less than eight milliseconds to provide increased arc flash hazard mitigation with equipment doors open or closed. Expected to be the fastest arcing fault containment technology in the industry, it can help reduce the occurrence and severity of work-related injuries and lost productivity.

 

The first release of Arc Vault system will feature an activation switch that can be used during routine maintenance to put the low-voltage equipment into a high-protection mode. When an arc flash event occurs, the system will send a signal to the arc containment device. The arc is then diverted to the containment system in less than one-half cycle or eight milliseconds. At the same time the decision to divert the arc is made, the system will also make a decision to open an upstream circuit breaker. This will turn off the system in approximately three cycles, at which point the arc in the containment system will terminate.

 

“Depending on site conditions, we estimate that this new option will enable the retrofit installation to be completed within a day,” said Foody.

 

Electrical shock and burn were responsible for the deaths of 2,287 U.S. workers and lost productivity from another 32,807 American employees during a seven-year period beginning in 1992 - nearly one fatality every day, according to a study by the Department of Labor’s Bureau of Statistics. Non-fatal injuries, 38% classified as electrical burns, caused an average of 13 days away from work.

 

“We’re excited about our ability to react quickly to the feedback received from customers and we are sure that all safety-conscious plant managers and consultants will welcome this arc protection technology that specifically addresses the arc flash hazard identified by the IEEE 1584 and NFPA 70E standards covering arc flash protection in the workplace,” said Foody.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.