Flow meter designed for precision measurement

FCI's ST75 Flow Meter is designed for process industry facilities and assembly plants and is also designed to reduce the consumption of energy fuel gases, specialty gases, and compressed air.

09/23/2011


FCI's ST75 flow meter is designed for precision flow in process industry facilities and assembly plants. Courtesy: FCIThe ST75 Flow Meter from Fluid Components International (FCI) is designed to deliver precision flow measurement while reducing the consumption of energy fuel gases, specialty gases and pneumatic air.

Installing ST75 Flow Meters in large process industry facilities and assembly plants with multiple gas compressors allows the operators to compare compressor usage and adjust them for optimum efficiency. In addition, the use of mass flow meters at the point of compressed gas output helps to ensure peak performance at a given flow rate. Comparing the performance of multiple gas compressors is also useful in predictive maintenance applications where higher flow rates may indicate leaking valves or seals in one unit versus other units operating under similar conditions.

The ST75 Flow Meter is designed for demanding process industry and manufacturing assembly plant environments. Offering an extensive set of standard features, the ST75 Flow Meter is designed for line sizes from 0.25 to 2.0 inches (6 to 51mm), which is ideal for compressor gas line measurement, and provides three unique outputs: the mass flow rate, totalized flow and media temperature.

The design includes media temperature compensation to ensure performance under variable process and plant temperature conditions. It offers accuracy to ±1% of reading and ±0.5% repeatability. Its precision flow element has a no-moving parts design that employs platinum RTD sensors embedded in equal mass thermowells with microprocessor electronics that can be calibrated to laboratory standards for CO2 as well as many other gases. 

Operating over a wide flow range, from 0.01 to 559 SCFM (0.01 to 950 NCMH) depending on line size, the ST75 Flow Meter is equally well suited for low flow and high flow applications. For variable process conditions, the ST75 is factory preset to a wide turndown range at 10:1 to 100:1.

The ST75 was developed with FCI’s thermal dispersion technology, providing direct-flow measurement, eliminating the need for temperature sensors, flow computers, or other devices that are required with orifice plates, Venturis, Vortex shedding, and other meters. Its no-moving parts design ensures superior service life. There are no orifices or inlets to clog or foul, which significantly reduces scheduled maintenance and unplanned shut-downs.

The ST75 Flow Meter offers fully scaleable 4-20mA and 0-10V outputs. They are user assignable to flow rate and/or temperature and a 0-1kHz pulse output of total flow. The instrument can be ordered for input power with either 18 to 36 Vdc or 85 to 265 Vac, with or without a built-in LCD digital display.

www.fluidcomponents.com 

Fluid Components International (FCI)

- Edited by Chris Vavra, Control Engineering, www.controleng.com 



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.