Compressed air: Find the leaks, lower the pressure, and measure the results

Create "good practices" around continuous monitoring of system leaks

By Mark Krisa, Ingersoll Rand

12/28/2012

1 of 3

Monitoring of your compressed air system usage is a great first step to identify where your issues might be. Courtesy: Ingersoll RandCompanies often face the challenge of identifying best practices for compressed air energy conservation by assessing the value others have realized while putting best practices into action. Without fail, every month brings an assortment of technical epiphanies, attempting to inspire the compressed air consumer with an audit expert’s secrets to success.

As an organization, Ingersoll Rand has audited thousands of systems worldwide. We routinely work with multinational companies to develop and execute strategies designed to deliver energy savings while simultaneously improving operational quality, reliability, and productivity. Leveraging this experience and associated results, we have identified what appears to be the “best” compressed air best practice of all.

For the purpose of ranking the quality or significance of any product or service, it is common to use a good, better, best segmentation. With this as a guide, some easy-to-execute energy conservation measures that may be considered good practices warrant consideration. By redefining these common practices as “good practices,” what is arguably the “best” best practice can be articulated without the redundant abuse of the word “best.” 

Find the leaks

The first “good practice” is an obvious one: reduce the quantity of compressed air associated with leaks. This is an energy conservation measure that is usually executed by an organization without having to enlist the services of a specialized service provider. In theory, this should be easy because fixing a leak does not require specialized skills or capital expenditure.

Ultrasonic leak detection equipment has been readily available for years, and many organizations have purchased the tools required to easily locate compressed air leaks of all sizes during normal production periods. This technology allows an operator to hone in on the specific acoustic characteristics of a compressed air leak and filter out all surrounding production noise. This has made finding leaks easy, but unfortunately finding a leak does not impact the energy required to support a compressed air system.


1 of 3

ROBERTO , TX, Brazil, 01/11/13 04:55 PM:

A no load test , made in a holiday gives you also a good measure of your invisible losses
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.