Boiler MACT rule now in effect

A Federal appeals court has ruled that the compliance date for the Boiler MACT rule for facilities is March 21, 2012.

02/03/2012


The District of Columbia Circuit Court of Appeals has reinstated the original compliance date for the Boiler MACT (maximum achievable control technology, also known as BMACT or Major Source Rule) that the EPA published in the Federal Register in March 2011. In a ruling on Jan. 9, 2012, District Court Judge Paul Friedman said that a delay of the rules was “arbitrary and capricious” and negated the delay. As a result, owners and operators of certain boilers and process heaters are required to meet work practice standards outlined in the rule by March 21, 2012 and install MACT equipment by March 2014.

Major source facilities are the ones affected by the newly reinstated Boiler MACT. A major source facility is one that emits 10 or more tons per year of any single air toxic or 25 tons or more per year of any combination of air toxics. A comprehensive list of the regulated air toxics can be found on the EPA website. Very large industrial facilities, such as refineries, chemical and large manufacturing plants, and large institutional facilities such as universities typically are classifed as major source facilities.

If a facility is not a major source, it is classified as an area source and is required to meet a different set of regulations that are in effect. For more information about the Area Source Rule, visit www.cleaverbrooks.com/epa.

Requirements for both major source and area source facilities vary depending upon: the type of fuel combusted, boiler commissioning date, and boiler size. For the Major Source Rule, EPA has identified 15 different subcategories of boilers and process heaters based on the design of the various types of units. The final rule includes specific requirements for each subcategory. Necessary actions range from conducting regular tune-ups to meeting numeric emissions limits. Facilities also must maintain records and file periodic reports to demonstrate compliance.

Below is a summary of the requirements of the Boiler MACT for major source facilities. For the complete rule that is published in the Federal Register, visit http://www.gpo.gov/fdsys/pkg/FR-2011-03-21/pdf/2011-4494.pdf 

- For all new and existing gas- and refinery gas-fired units, the operator must perform an annual tune-up for each unit. Units combusting other gases can qualify for work practice standards by demonstrating that they burn “clean fuel,” with contaminant levels similar to natural gas.

- For all new and existing units with a heat input capacity less than 10 MMBtu/hr, the operator is required to perform a tune-up for each unit once every two years.

- For all new and existing “limited use” boilers (defined as those operated less than 10 percent of the year as emergency and back-up boilers to supplement process power needs), the operator is required to perform a tune-up for each unit once every two years.

- The final rule establishes numeric emission limits for all other existing and new boilers and process heaters located at major sources. The final rule establishes emissions limits for:

  • Mercury
  • Dioxin
  • Particulate matter (PM) as a surrogate for non-mercury metals
  • Hydrogen chloride (HCI) as a surrogate for acid gases 
  • Carbon monoxide (C) as a surrogate for non-dioxin organic air toxics.

- The largest major source boilers are required to continuously monitor their particle emissions. All units larger than 10 MMBtu/hr must monitor oxygen as a measure of good combustion.

- Existing major source facilities are required to conduct a one-time energy assessment to identify cost-effective energy conservation measures.

While the Area Source Rule has been in effect since being published in March 2011, the Major Source Rule has not. In May 2011, EPA issued a notice of delay and asked for a stay of the rules to give the agency more time to evaluate feedback from the industry.

In July 2011, the Sierra Club petitioned the appellate court for review of the EPA’s delay notice, contending that the original rules will help reduce illnesses such as lung cancer and asthma. EPA issued a revised proposal in December 2011 that agency officials said is less costly for affected boiler owners than the original proposal, but still meets the necessary requirements laid out in the 1990 Clean Air Act amendments. However, Judge Friedman’s ruling reinstates compliance deadlines set in the earlier March 2011 rule.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2013 Leaders here.
The new control room: It's got all the bells and whistles - and alarms, too; Remote maintenance; Specifying VFDs
2014 forecast issue: To serve and to manufacture - Veterans will bring skill and discipline to the plant floor if we can find a way to get them there.
2013 Top Plant: Lincoln Electric Company, Cleveland, Ohio
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Bring focus to PLC programming: 5 things to avoid in putting your system together; Managing the DCS upgrade; PLM upgrade: a step-by-step approach
Balancing the bagging triangle; PID tuning improves process efficiency; Standardizing control room HMIs
Commissioning electrical systems in mission critical facilities; Anticipating the Smart Grid; Mitigating arc flash hazards in medium-voltage switchgear; Comparing generator sizing software

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.