APC Symmetra PX 250/500kW supports parallel configurations up to 2000kW

The Symmetra PX250/500kW offers a modular, hot-scalable system consisting of dedicated and redundant modules.

01/27/2011


APC by Schneider Electric, a producer of integrated critical power and cooling services, new parallel capabilities of the Symmetra PX 250/500kW three-phase modular and hot scalable uninterruptible power supply (UPS). Schneider Electric APC Symmetra PX This new firmware ships standard on all Symmetra PX250/500kW units which can now be paralleled to deliver up to 2 MW of power protection, or 1.5MW in a system level redundancy (N+1) configuration. The Symmetra PX250/500kW reportedly provides unprecedented scalability and availability up to 2000 kW, giving customers the unrivalled flexibility to scale their data centers as business needs require.

The Symmetra PX250/500kW offers a modular, hot-scalable system consisting of dedicated and redundant modules - power, intelligence, battery and communications - all engineered into a design that allegedly makes installation, future expansion and serviceability faster and easier. Each system is scalable in 25kW increments up to 500kW with the ability to run up to four systems in parallel to provide 2MW of redundant power protection. The architecture gives IT managers the ability to right-size power and runtime as demand grows or as higher levels of availability dictate.

In addition to all the current features and reported capabilities of the Symmetra PX250/500kW - independently verified efficiency of greater than 96% down to 35% loading, high density space saving design, modular, hot scalable with a system-wide mean time to repair of less than 10 minutes, and near silent operation - the release of this new firmware adds:

  • Parallel up to 4 units - for 2000kW or 1.5MW in an N+1 system configuration of power protection capacity.
  • Energy monitoring – Has the ability to calculate and display the energy (kWh) delivered on the output of each unit.
  • Multi-language support – can be localized in seven languages to provide better understanding of alarms/events and display information.
  • Shortened recharge time – 20% charge capacity at loads less than 100%, can be used to recharge units for faster recovery and to maximize system availability.

The Symmetra PX250/500kW can be managed through APC’s InfraStruxure Management Software Portfolio and can be integrated into data centers for a complete solution through built-in management software including InfraStruxure Designer, Central, Capacity Manager, and server access support.

www.apc.com

APC by Schneider Electric

www.schneider-electric.us Schneider Electric



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. The 2012 Top Plant winners have been named.
In 2012, Plant Engineering's Product of the Year program will celebrated its 25th anniversary. Read about the 2012 winners and nominate for 2013.
The Leaders Under 40 program features outstanding young people who are making a difference in manufacturing. View the 2012 Leaders here.
Investment in excellence: One plant's improved productivity and quality was repaid when their company expanded the facility
Strategic uptime, Increased capacity goes right to the bottom line
2013 Forecast Issue: A shift in manufacturing
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Alarm management tips, Power management, Building automation
Estimating data center PUE, Design tips for cost savings, Networked controls, NFPA 70E
Attacking Energy Costs: Strategies for showing financial return on energy management investments

2012 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

About Us | Contact Us | Advertise | Subscribe to Magazine | Site Map | Privacy Policy
Home | Channels | New Products | Media Library | Connect | Industry News | Events and Awards | Newsletters | Blogs | Magazine
Control Engineering | Plant Engineering | Consulting-Specifying Engineer
All content copyright © 2010-2013 CFE Media. All rights reserved.