10 benefits of using adjustable speed drives

Adjustable speed drives can be used in most applications where motors power mechanical equipment. Drives provide precise electrical motor control, enabling motor speeds to be ramped up and down or maintained at a required speed. The obvious benefit is the motor and drive use only the require amount of energy, rather than having a motor run at a fixed speed.

11/11/2010


 

Adjustable speed drives can be used in most applications where motors power mechanical equipment. Drives provide precise electrical motor control, enabling motor speeds to be ramped up and down or maintained at a required speed. The obvious benefit is the motor and drive use only the require amount of energy, rather than having a motor run at a fixed speed.

 

As energy supplies become increasingly strained, controlling motors based on the actual demands of the load also becomes increasingly important. One would think that saving 25% to 70% of the energy cost for driving motorized equipment, that more facilities would use adjustable speed drives.

 

Not convinced? Consider these 10 benefits of operating motors with adjustable speed drives:

 

1. Controlled starting current. When an ac motor is started “across the line,” it takes as much as seven-to-eight times the motor full-load current to start the motor and load. But when using an adjustable speed drive, the substantially reduced starting current extends the life of an ac motor. The payback is less wear and tear on the motor, which translates to extended motor life and less motor rewinds.

 

2. Reduced power line disturbances. Starting an ac motor across the line and the demand for starting current places an enormous drain on the power distribution system connected to the motor. Typically, the supply voltage sags, which can cause sensitive equipment connected on the same distribution system to trip. Items such as computers, sensors, proximity switches and contactors are voltage sensitive and can drop out when a large ac motor is started nearby. Using an adjustable speed drive eliminates this voltage sag.

 

3. Lower power demand on start. The power needed to start an ac motor across the line is significantly higher than with an adjustable speed drive. This is true only at start, since the power to run the motor at load would be equal regardless if it were fixed speed or variable speed.

 

4. Controlled acceleration. An ac motor started across the line is a tremendous mechanical shock for the motor and connected load. This shock increases the wear and tear on the connected load as well as the motor. Some applications such as bottling lines cannot be started with motors across the line, but must be started empty to prevent breakage. However, an adjustable speed drive starts at zero speed and accelerates smoothly on a user-adjustable ramp.

 

5. Adjustable operating speed. Using an adjustable speed drive enables process optimization and making changes in a process. It also allows starting at reduced speed and allows remote adjustment of speed by programmable controller or process controller.

 

6. Adjustable torque limit. Using an adjustable speed drive can protect machinery from damage and protect the process or product because the amount of torque being applied by the motor to the load can be controlled accurately. For example, if a machine jams, the motor connected across the line will continue to try to rotate until the motor's overload device opens. An adjustable speed drive can be set to limit the amount of torque so the motor never exceeds this limit.

 

7. Controlled stopping. Controlled stopping helps reduce product loss due to breakage or mechanical wear and tear attributed to shocks to the process.

 

8. Energy savings. Centrifugal fan and pump loads operated with adjustable speed drives reduce energy consumption. If the speed of a fan is cut in half, the horsepower required to run the fan is cut by a factor of eight. The energy savings could relate to a return on investment of less than two years.

 

9. Reverse operation. Using an adjustable speed drive eliminates the need for a reversing starter, since the output phases to the motor can be electronically changed without mechanical devices. Eliminating the reversing starter eliminates its maintenance cost and reduces panel space.

 

10. Elimination of mechanical drive components. Using an adjustable speed drive can eliminate the need for expensive mechanical drive components such as gearboxes. Because the ac drive can operate with an infinite variable speed, it can deliver the low- or high-speed required by the load without speed-varying devices between the motor and load. This eliminates maintenance costs as well as reducing floor-space requirements.

 

Adapted from ABB Inc.

 

These drives control forced-draft and flue-gas recovery fans.



No comments
The Top Plant program honors outstanding manufacturing facilities in North America. View the 2013 Top Plant.
The Product of the Year program recognizes products newly released in the manufacturing industries.
The Engineering Leaders Under 40 program identifies and gives recognition to young engineers who...
The true cost of lubrication: Three keys to consider when evaluating oils; Plant Engineering Lubrication Guide; 11 ways to protect bearing assets; Is lubrication part of your KPIs?
Contract maintenance: 5 ways to keep things humming while keeping an eye on costs; Pneumatic systems; Energy monitoring; The sixth 'S' is safety
Transport your data: Supply chain information critical to operational excellence; High-voltage faults; Portable cooling; Safety automation isn't automatic
Case Study Database

Case Study Database

Get more exposure for your case study by uploading it to the Plant Engineering case study database, where end-users can identify relevant solutions and explore what the experts are doing to effectively implement a variety of technology and productivity related projects.

These case studies provide examples of how knowledgeable solution providers have used technology, processes and people to create effective and successful implementations in real-world situations. Case studies can be completed by filling out a simple online form where you can outline the project title, abstract, and full story in 1500 words or less; upload photos, videos and a logo.

Click here to visit the Case Study Database and upload your case study.

Maintaining low data center PUE; Using eco mode in UPS systems; Commissioning electrical and power systems; Exploring dc power distribution alternatives
Synchronizing industrial Ethernet networks; Selecting protocol conversion gateways; Integrating HMIs with PLCs and PACs
Why manufacturers need to see energy in a different light: Current approaches to energy management yield quick savings, but leave plant managers searching for ways of improving on those early gains.

Annual Salary Survey

Participate in the 2013 Salary Survey

In a year when manufacturing continued to lead the economic rebound, it makes sense that plant manager bonuses rebounded. Plant Engineering’s annual Salary Survey shows both wages and bonuses rose in 2012 after a retreat the year before.

Average salary across all job titles for plant floor management rose 3.5% to $95,446, and bonus compensation jumped to $15,162, a 4.2% increase from the 2010 level and double the 2011 total, which showed a sharp drop in bonus.

2012 Salary Survey Analysis

2012 Salary Survey Results

Maintenance and reliability tips and best practices from the maintenance and reliability coaches at Allied Reliability Group.
The One Voice for Manufacturing blog reports on federal public policy issues impacting the manufacturing sector. One Voice is a joint effort by the National Tooling and Machining...
The Society for Maintenance and Reliability Professionals an organization devoted...
Join this ongoing discussion of machine guarding topics, including solutions assessments, regulatory compliance, gap analysis...
IMS Research, recently acquired by IHS Inc., is a leading independent supplier of market research and consultancy to the global electronics industry.
Maintenance is not optional in manufacturing. It’s a profit center, driving productivity and uptime while reducing overall repair costs.
The Lachance on CMMS blog is about current maintenance topics. Blogger Paul Lachance is president and chief technology officer for Smartware Group.